SUMMARY: SCSI transport failed

From: Eric Walters (eric.walters@sdrc.com)
Date: Thu Feb 13 1997 - 13:48:59 CST


My original message,

>
> Sun managers,
>
> I have an Ultra1 (Creator 3D) thats been causing me serious pain lately.
> The root hard drive sporatically spins down, locking any process
accessing
> it, and then spins backup leaving the following message in it wake.
>
> --/u/eihatton > WARNING: /sbus@1f,0/SUNW,fas@e,8800000 (fas0):
> Disconnected tagged cmd(s) (4) timeout for Target 1.0
>
> WARNING: /sbus@1f,0/SUNW,fas@e,8800000/sd@1,0 (sd1):
> SCSI transport failed: reason 'timeout': retrying command
>
> WARNING: /sbus@1f,0/SUNW,fas@e,8800000/sd@1,0 (sd1):
> SCSI transport failed: reason 'reset': retrying command
>
> WARNING: /sbus@1f,0/SUNW,fas@e,8800000 (fas0):
> target 1: failed reselection (no command)
>
> WARNING: /sbus@1f,0/SUNW,fas@e,8800000/sd@0,0 (sd0):
> SCSI transport failed: reason 'reset': retrying command
>
> WARNING: /sbus@1f,0/SUNW,fas@e,8800000/sd@1,0 (sd1):
> Error for command 'read(10)' Error Level: Fatal
> Requested Block 3041776, Error Block: 3041776
> Sense Key: Not Ready
> Vendor 'SEAGATE':
> ASC = 0x4 (LUN not ready), ASCQ = 0x2, FRU = 0x2
> .....
>
> I've replace both harddrives, motherboard, powersupply, installed all
> recommended patches and scrifices a chicken and the thing is still acting
up.
>
> Any ideas?
> ETR - Eric The RED
> Eric.Walters@sdrc.com

I got a number of responses refering to scsi cable length, and termination.
The closest was from Matthew Stier
>Internal cable damage?

It turns out the hard drive power/communication assembly had a fractured
sodering point located at the power plug from the powersupply. Wiggleing the
wire would cause the lights on the hard drives to go out and was the traced to
the actual plug.

Much thanks to the following for their support
Shridhar Deuskar
Kris Briscoe
Per Boussard
Marc Bibian
James Brigman
Matthew Stier

ETR



This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:11:46 CDT